Powered Foundation Vents

 

Foundation vents help remove moisture that can lead to damp rot and eventually costly damage, as well as attract termites.

 

Foundation Vents

Description

Foundation vents help remove moisture that can lead to damp rot and eventually costly damage, as well as attract termites.

Powered foundation vents are extremely effective in providing ventilation for moisture control.

A small fan is encased in the housing of the vent and runs continuously at a low speed when the humidity level exceeds the setting on the humidistat. The fan creates negative pressure in the foundation to pull air through the foundation. Powered vents are installed on one side of the foundation, with open, non-powered vents on the other side.

 

Low Voltage Powered Foundation Vents and Radon Powered Foundation Vents

  • 8″ x 16″ to fit into a standard block opening
  • Completely screened, front and back
  • No mortar required for installation
  • Totally enclosed, thermally protected motor
  • Low voltage unit - no electrician required

*Series 5 & 6 Requires controls kit – sold separately

 

Controls Kit 

 Controls Kit

  • Damp Weather Shutoff – dual control adjusts temperature & humidity at intake vent
  • Humidistat – turns unit on to mitigate humidity
  • Power Supply Unit – 24 VAC output, operates up to 3 power vents
  • Control Cables – 25' attaches all control kit units together


KIT REQUIRED ON ALL SERIES 5 AND 6 LOW VOLTAGE
FOUNDATION VENTS (needs accessible GFCI outlet)

 

RELATED DOCUMENTS

 

Specifications

 

Color Model Part No. CFH Pcs/Ctn
Series 6, High Output Black TV6LVHPBL 94004 300 rpm
1.0 amps, 24 volts
11,160 cubic ft./hr.
 1
Series 6, Quiet Black TV6LVQPBL 94005 1550 rpm
0.9 amps, 24 volts
7,200 cubic ft./hr.
 1
Series 5, High Output
removable front frame
Black TV5LVHPBL 94002 3000 rpm
1.0 amps, 24 volts
11,160 cubic ft./hr.
 1
 
Controls Kit
Kit required on all Series 5 and 6
low voltage foundation vents (sold separately)
  LVKIT 94001   1
           
 Accessories  Color  Model     Pcs/Ctn 
Vent Well Black VWBL     1

 Powered Foundation Vent Colors

 

 

 

Warranty

WARRANTY

Learn about warranty coverage, transferability, limitations, other conditions and customer responsibilities.

 

Read the full warranty and the list of eligible products.

 

For Warranty information and questions, please contact us at: warranty@gibraltar1.com 

 

Limited Warranty
The Air Vent Product that you have purchased has a limited warranty from the date of purchase against defects in workmanship and materials. The length of the warranty varies by product. Please see attached chart for details. Any part believed to be defective must be returned to the factory (Air vent, Inc., 4117 Pinnacle Point Dr, Suite 400, Dallas, Texas 75211) freight prepaid. If found to be defective following examinations, any defective part will be replaced free of charge and returned freight prepaid. This warranty does not cover any labor costs, including those required for field repair or replacement or removal of any allegedly defective part.

 

Limitations
Air Vent shall not be liable for, and this warranty does not apply to, any failure, defect or damage resulting from or connected with misuse, abuse, neglect or improper handling or staging , or installation not in strict adherence to Air Vent’s written instructions; impact of foreign objects, fire, flood, earthquake, lightning, hurricane, hail, tornado or other violent storms or other act of God; or defects in failure of or damage caused by materials used as roofing base over which the product is installed or by movement, distortion, cracking or settling of walls or the foundation of the building.

Air Vent reserves the right to discontinue or modify any of its products including color, and shall not be liable as a result of such discontinuation or modification, nor shall Air Vent be liable in the event replacement material may vary in color in comparison to the original product as a result of normal weathering. If Air Vent replaces any product under this warranty, it may substitute products designated by Air Vent to be of comparable quality or price range in the event the product initially installed has been discontinued or modified.

 

Replacement Plus™ Protection
Products are covered by Replacement Plus™ protection (see attached for applicable products) for a period of time (varies by product) provided that the product has been installed in strict accordance with Air Vent’s written installation instructions. Under this warranty feature, Air Vent, at no charge, will replace any product found to be defective during the Replacement Plus™ period (Replacement Plus™ period begins when the product installation is completed). Air Vent’s maximum liability under Replacement Plus will be equal to the reasonable cost to replace the defective product, including labor.

In instances in which Air Vent, according to the terms of this warranty, has agreed to pay the cost of labor required to replace a defective intake vent, Air Vent will provide reimbursement only upon receipt of a copy of the contractor’s invoice or other written evidence of the completion of the work which Air Vent, at its sole discretion, deems acceptable.

 

Transferability
Provided that the products covered by this warranty have been installed in strict accordance with the Air Vent Inc. written installation instructions and in accordance with all local codes and standards, including those pertaining to fire-rated construction, Air Vent warrants to the original purchaser or first subsequent owner of the property that the product is free from manufacturing defects for the described length below from the date of purchase. If there is a change in ownership, the warranty may be transferred by the original purchaser of the product to the new owner (first subsequent owner) under the terms and conditions of this warranty.

 

Motor Replacements
The electrical motor is to be used solely as a direct replacement for a motor of the same model in an Air Vent, Inc, power attic ventilator. Using the motor in any other product could result in electrical shock and/or fire, which may cause property damage, serious injury or even death. Any motor replacement should be installed by a qualified licensed electrician in accordance with local, state and national electrical codes and standards. Make sure that power to the unit has been completely turned OFF at the breaker before approaching or inspecting the power attic ventilator or installing the replacement motor.

 

Other Conditions
This warranty is expressly in lieu of all other oral or written warranties, liabilities or obligations of Air Vent. Pertinent state law shall control for what period of time subsequent to sale a consumer/homeowner may seek a remedy pursuant to the implied warranty of merchantability or fitness for a particular purpose. In no event shall Air Vent be liable for consequential or incidental damages of any kind, including any damage to the building, its contents or any persons therein, resulting from the breach of any warranty set forth herein, unless exclusion of these types of damages are specifically prohibited by state law. No field representative of Air Vent or any distributor or dealer is authorized to make any change or modifications to this warranty. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

 

The following warranty is effective 6/23/2017.

 Product  Warranty  Replacement Plus Protection
 ShingleVent ®II ridge vent (12", 9", 7", Class A 9" and 7") Limited Lifetime Warranty 5 year Replacement Plus™ protection

 Peak Performer™ I & II Rolled ridge vent Limited Lifetime Warranty 5 year Replacement Plus™ protection

 Multi-Pitch FilterVent® ridge vent Limited Lifetime Warranty 5 year Replacement Plus™ protection

 The Edge™ Vent Limited Lifetime Warranty 5 year Replacement Plus™ protection

 Hip Ridge® Vent Limited Lifetime Warranty 5 year Replacement Plus™ protection

 VenturiVent™ Plus ridge vent Limited Lifetime Warranty 5 year Replacement Plus™ protection

 VenturiVent™ Rolled ridge vent Limited Lifetime Warranty 5 year Replacement Plus™ protection

 ATTIC-AIRE™ ALL SEASONS™ Filtered Ridge Vent and Roll Vent Limited Lifetime Warranty 5 year Replacement Plus™ protection

 Power Cool Plus™ Power Attic Ventilator- model PC15 Limited Lifetime Warranty 5 year Replacement Plus™ protection

 Power Cool Plus™ Power Attic Ventilator- model PC12 10 Year Limited Warranty 5 year Replacement Plus™ protection

 Power Cool™ Power Attic Ventilator- model BR28 10 Year Limited Warranty 5 year Replacement Plus™ protection

 Power Cool™ Power Attic Ventilator- model BR26 5 Year Limited  2 year Replacement Plus™ protection

 Solar Power Fan- (models NPSP8WW, SC8BL, NPSG8) 5 Year Limited Warranty 2 year Replacement Plus™ protection

 Gable-Mount Power Fans (APG, APGH)- with Humidistat Limited Lifetime Warranty 5 year Replacement Plus™ protection

 Gable-Mount Power Fans (WCGB)- with Thermostat 10 Year Limited Warranty 5 year Replacement Plus™ protection

 Gable-Mount Power Fans (model WCGA) 5 Year Limited Warranty 2 year Replacement Plus™ protection

 Gable-Mount Power Fan Solar (NPSG8) 5 Year Limited Warranty 2 year Replacement Plus™ protection

 Gable-Mount 20 Watt Solar Fan (1020APV) 5 Year Limited Warranty on Fan Motors 20 Year Limited on Solar Panel, Fan Housings

 Whole-House Fans 10 Year Limited Warranty 5 year Replacement Plus™ protection

 Roof Mount Power Vent (ASRHP, SV3000) Limited Lifetime Warranty 5 year Replacement Plus™ protection

 Roof Mount Power Vent (RV26, RV28) 10 Year Limited Warranty 5 year Replacement Plus™ protection

 Roof Mount Power Vent (NPSP8WW, SC8BL) 5 Year Limited Warranty 2 year Replacement Plus™ protection

 Automatic Foundation Vent 5 Year Limited Warranty  

 Heavy Duty Automatic Foundation Vent 5 Year Limited Warranty  

 Powered Foundation Vent 5 Year Limited Warranty  

 Ridge Vent 20’ Limited Lifetime Warranty  

 Airhawk® Wind Turbines (TIB, TOB series) Limited Lifetime Warranty  

 Attic Aire™ Wind Turbines (WT series) 5 Year Limited Warranty  

 Airhawk® Static Vents (RVG55, B144) 5 Year Limited Warranty  

 Low Voltage Foundation Vent (Series 5 & 6, Radon) 5 Year Limited Warranty  

 Solar Power Fan (AV9912TR, AV9920TR, AV9930TR) 5 Year Limited Warranty on Fan Motors 20 Year Limited on Solar Panel, Fan Housings

 Skylight Tubes (1914ST, 2114ST) 10 Year Limited Warranty  

US Sunlight Solar Controller (SC20) 1 Year Limited Warranty on Unit, Remote  

 

Accessories

Humidistats and Thermostats -- A humidistat and thermostat can be installed with the vent to run the fan intermittently. The humidistat turns the fan on when moisture in the foundation rises to a pre-set level. A thermostat should also be connected to the fan to turn the fan off in freezing weather to protect pipes under the home and to save energy.

Call customer service at 1-800-AIR-VENT for more information.

 

Product Photos

PRODUCT PHOTOS

Click an image to enlarge:

 

 

 

 

Product Categories
Exhaust Vents Solar Attic Fans Intake Vents Foundation Vents Whole House Fans Bath or Dryer Vents Skylight Tubes
 
Air Vent Contractor LocatorOur exclusive Contractor Locator will allow you to find contractors in your area who can assist with Air Vent product installation—including solar attic fans and skylight tubes. Click the link below to register and get started.

 

Search for Contractors