Specifications
Ridge Vents
When installed properly, all Air Vent products mentioned here comply with the net free area requirements of nationally recognized model codes, including those written by the International Code Council. In addition, some of the vents have product evalutation approvals from specific code bodies.
Please call 1-800-AIR-VENT to obtain code body information for a particular Air Vent product.
Here's an overview of the specifications for Air Vent's complete line of ridge ventilation products.
View the wide range of colors in which our products are available in our color chart.
| Product | Model | Description | Colors | Size | Net Free Area | Roof Pitch |
| ShingleVent II | SHFV203, 12" wide |
Shingle-over ridge vent |
Black, Brown, Gray, Charcoal |
4' | 18 sq. in. per ft. | 3/12 to 16/12 |
| ShingleVent II-9 | SHFV209, 9" wide |
Shingle-over ridge vent |
Charcoal | 4' | 16 sq. in. per ft. | 3/12 to 12/12 |
| ShingleVent II-7 | SHFVII-7, 7" wide |
Shingle-over ridge vent |
Charcoal | 4' | 16 sq. in. per ft. | 3/12 to 12/12 |
| ShingleVent II-9A | CLASH9CC, 9" wide |
Shingle-over ridge vent |
Charcoal | 4' | 16 sq. in. per ft. | 3/12 to 12/12 |
| ShingleVent II-7A | CLASH7CC, 7" wide |
Shingle-over ridge vent |
Charcoal | 4' | 16 sq. in. per ft. | 3/12 to 12/12 |
| Multi-Pitch FilterVent |
FV101 | Aluminum ridge vent |
Black, Brown, White, Gray, Mill, Bronze, Zinc, Copper |
10'* | 18 sq. in. per ft. | 3/12 to 12/12 |
| FV110 | Aluminum ridge vent |
Black, Brown, White, Gray, Mill, Bronze, Zinc, Copper |
8'* | 18 sq. in. per ft. | ||
| Hip Ridge™ Vent
NEW! |
HIPVBL | Shingle-over ridge vent for diagonal hips |
Black | 4' | 12 sq. in. per ft. | 3/12 to 16/12** |
| VenturiVent Plus™ | VVP | Shingle-over ridge vent |
Black | 4' | 18 sq. in. per ft. | 3/12 to 16/12 |
| VenturiVent Plus™ with Nails NEW! |
VVPN | Shingle-over ridge vent with a bag of 30 3-inch ring shank nails taped to each 4-foot piece. |
Black | 4' | 18 sq. in. per ft. | 3/12 to 16/12 |
| Peak Performer™ I | PPI | Shingle-over ridge vent in a roll (unfiltered) | Black | 28' | 12 sq. in. per ft. | 3/12 to 12/12 |
| Peak Performer™ II | PPII | Shingle-over ridge vent in a roll (filtered) | Black | 28' | 12 sq. in. per ft. | 3/12 to 12/12 |
| VenturiVent Roll | VVR20 | Shingle-over ridge vent in a roll (unfiltered) | Black | 20' | 12 sq. in. per ft. | 3/12 to 12/12 |
| Peak FilterVent | PVF152 | Aluminum peak vent for contemporary roof designs | Black, Brown, Gray, Bronze |
Venting Pack | 9 sq. in. per ft. | 3/12 to 12/12 |
| Flash FilterVent |
FFV162 | Aluminum vent for roof/wall junctions | Black, Brown, Gray, Bronze, Copper |
Venting Pack | 9 sq. in. per ft. | 3/12 to 12/12 |
| Utility FilterVent | UFV172 | Aluminum vent for specialty applications | Black, Brown, Gray, Bronze |
Venting Pack | 9 sq. in. per ft. | 3/12 to 16/12 |
Venting packs contain four eight-foot pieces, two end plugs, three connector plugs and straps. Flash FilterVent includes four pieces of Supplemental Flashing.
Note: Venting packs can be shipped UPS, except Zinc and Copper.
* Also available in venting packs.
**The adjacent decks forming the hip ridge (the diagonal/ridge) must be minimum 3/12 pitch. The common rafter roof pitch must be 5/12 to 16/12.
Designing The Balance System™ For Attic Ventilation
Research has shown that the best way to ventilate an attic is with a system that provides continuous airflow along the entire underside of the roof sheathing. Achieving this desired airflow requires a balanced system of intake ventilation low at the roof's edge or in the soffit/eaves and exhaust ventilation at the ridge. Air Vent offers a variety of high performance intake vents including our NEW Edge™ Vent.
For optimum attic ventilation for today's tighter built, tighter remodeled homes that have more efficient building materials, Air Vent recommends exceeding minimum building codes.* Air Vent recommends 1 square foot of ventilation for every 150 square feet of attic floor space with half the ventilation represented by intake vents and half by exhaust vents such as ridge vents.
To determine how many feet of net free area you need for a balanced ridge vent/intake vent system, use this formula:
| Sq. ft. of attic floor space 150 |
= | Sq. ft. of net free area needed |
To determine how many linear feet of Air Vent's ShingleVent II you need, use this formula:
½ net free area needed x 144 / 18 = minimum feet of ShingleVent II
To determine how many linear feet of Air Vent's NEW Edge Vent intake you need, use this formula:
½ net free area needed x 144 / 9 = minimum feet of The Edge Vent
* For minimum building code requirements use the 1/300 ratio instead of the 1/150 ratio.
Appendix: Ridge Vent/Intake Vent Calculator for Standard Gable Attic*
*An electronic version of this calculator is available here.
To use this calculator, first find the total square footage of the attic floor area. Round your calculations up to the next highest number (see Appendix A).
Then look across to the number under the Minimum Length of Ridge column. That tells you the total linear feet of ridge vent required using the 1/300 minimum code requirements. Note: Because today's tighter homes require more airflow, the 1/150 ratio is also included in Appendix A.
To balance your ridge vent system, find the length of the ridge and follow the column to the right for required intake vents (see Appendix B).
Appendix A: Ventilation Requirements
| Attic Square Footage |
Minimum Length of Ridge at 1/300 ratio |
Minimum Length of Ridge at 1/150 ratio |
| 1200 | 16 | 32 |
| 1500 | 20 | 40 |
| 1800 | 24 | 48 |
| 2100 | 28 | 56 |
| 2400 | 32 | 64 |
| 2600 | 36 | 72 |
| 3000 | 40 | 80 |
| 3300 | 44 | 88 |
Note: Calculations are based on ShingleVent II and Multi-Pitch FilterVent which provide 18" of net free area per linear foot.
Appendix B: Balancing Your Ridge Vent System
| Length of Ridge |
Linear Feet of The Edge Vent shingle-over intake |
Number of Undereave Vents | ||
| 16"x8" | 16"x6" | 16"x4" | ||
| 15' | 30 | 5 | 6 | 10 |
| 20' | 40 | 6 | 9 | 13 |
| 30' | 60 | 10 | 13 | 19 |
| 40' | 80 | 13 | 17 | 26 |
| 50' | 100 | 16 | 21 | 32 |
| 60' | 120 | 19 | 26 | 39 |
| 70' | 140 | 23 | 30 | 45 |
| 80' | 160 | 26 | 34 | 51 |
| 90' | 180 | 29 | 39 | 58 |
Note: FHA requirements and most building codes state the minimum required net free area. This minimum ventilation area may not be enough to effectively ventilate the attic to prevent moisture damage and cool the attic enough in the winter to prevent ice dams.
Specifications | Warranty | Product Videos | ShingleVent II-7 Drawing Detail | ShingleVent II-9 Drawing Detail